Filter Results By:

Products

Applications

Manufacturers

Showing results: 76 - 90 of 123 items found.

  • Active Filter

    J2190A - PICOTEST Corp.

    The J2190A active filter presents a high impedance (approximately 150kOhms) minimizing the loading of the circuit being tested. The output impedance is 50 Ohms allowing low noise coaxial connections to all typical test equipment. The 0.1Hz-10Hz noise band is common for opamp measurements, voltage regulators and voltage references. Many application notes offer schematics of such a filter for test purposes. An engineer’s time is much too valuable to be spent building test equipment. We have created a 4th order high pass and 4th order low pass filter with an optimally flat response and 0dB gain. Additional filters can be cascaded for even sharper cutoff.

  • Data Converter ICs

    Microchip Technology Inc.

    We offer a complete range of high-performance, low-power,and small-size data converter integrated circuits (ICs) for demanding industrial, automotive and consumer applications. Whether you need an Analog-to-Digital Converter (ADC), Digital-to-Analog Converter (DAC), digital potentiometer, AC and DC power and energy measurement device, voltage reference or a combinationof data converter ICs, we have the right solution for your application and world-class support to make sure you meet your design goals.

  • Digital to Analog Converter

    Texas Instruments

    20-bit digital-to-analog (D/A) converter offering 20-bit monotonic performance over the specified temperature range. It utilizes delta-sigma technology to achieve inherently linear performance in a small package at very low power. The resolution of the device can be programmed to 20 bits for Full-Scale, settling to 0.003% within 15ms typical, or 16 bits for Full-Scale, settling to 0.012% within 2ms max. The output range is two times the external reference voltage. On-chip calibration circuitry dramatically reduces low offset and gain errors.

  • Dual Channel HV Amplifier with Phase Inverter

    A400DI - FLC Electronics Inc

    This unit contains two independent A400 amplifiers that share common ground reference and power supply. Please see A400 page for technical details.It features also a low voltage phase inverter that inverts the signal applied to the input of channel 1. The resulting signal can then be connected to the input of channel 2 by means of a short BNC cable (supplied). As a result the two outputs operate in counter-phase. Connecting a load between the outputs effectively doubles the amplitude range. Please note that the load cannot have any connection to ground.

  • Instrumentation Amplifiers

    Analog Devices Inc.

    Analog Devices instrumentation amplifiers (in-amps) are precision gain blocks that have a differential input and an output that may be differential or single-ended with respect to a reference terminal. These devices amplify the difference between two input signal voltages while rejecting any signals that are common to both inputs. The in-amps are widely used in many industrial, measurement, data acquisition, and medical applications where dc precision and gain accuracy must be maintained within a noisy environment, and where large common-mode signals (usually at the ac power line frequency) are present.

  • Impedance Standards and Calibrators

    MEATEST, s.r.o.

    Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.

  • IC/BGA Tester

    Focus-2005 - Kyoritsu Testsystem Co., Ltd.

    As a screening checker to detect defective devices(mainly electrostatic destruction)which are returned from fields before failure analysis process of IC/LC in the quality assurance division of semiconductor manufacture.As a screening checker to detect defective devices before acceptance inspection by IC/LSI expensive tester at semiconductor company(trading, manufacture)Short/Open checker for semiconductor sensor device.It is possible to measure two kinds of measurements which are constant voltage biased current measurement and constant current biased voltage measurement. User can set the threshold of 10 ranks. (auto measurement)Only device can be measured. It is also possible to fabricate the test fixture.Various devices can be measured by replacing the socket board.It is no need to generate complex test programs as reference values are calculated from good device.It can be expanded by adding multiplexer boards which are 128pins per one board.(MAX 2048pins)

  • Digital Multimeters

    Meco Instruments Pvt. Ltd.,

    Multi-Display : Primary 80000, Secondary 80000, Bargraph 23 SegmentsBasic DC Accuracy : 0.05% mV Impedence : > 1000M OhmMore than 50 Measuring FunctionsFrequency Measurement : 0.5Hz to 8.0000MHz 16 Frequency Points, 1% to 99% Duty. Selectable Square Wave OutputAnalyzing Component of Current or Voltage SignalResistance : 0.1Ω to 80MΩ, 10MΩ to 8000MΩCapacitance : 1nF to 100µFTemperature : -50°C to 1372°C, -58°F to 2502°F dBm 20 Types of Reference ImpedenceAuto Data Hold / Peak HoldRelative Measurement36 Hours Dynamic Recording : MAX / MIN / AVG/ MAX-MINCommunication : Isolated Optical RS-232Timer for MeasurementBacklight DisplayAuto Power Off

  • Complete Field Meter Site Testing Solution

    7 Series - Powermetrix Systems

    We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.

  • C Series Relay Output Module

    NI

    The C Series Relay Output Module enables you to switch up to eight signals at 60 V maximum DC switching voltage and up to 250 V of maximum AC switching current. For quick reference, every channel features an LED to indicate the state of that channel. The C Series Relay Output Module allows for direct connection to a wide array of industrial devices such as motors, actuators, and DC devices.The C Series Relay Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Xilinx Zynq ARM + FPGA SoM

    TE0720 - Sundance Multiprocessor Technology Ltd.

    TE0720s are industrial-grade SoC modules integrating a Xilinx Zynq Z020 SoC, a gigabit Ethernet transceiver (physical layer), 8 Gbit (1 Gbyte) DDR3 SDRAM with 32-bit width, 32 Mbyte Flash memory for configuration and operation, and powerful switch-mode power supplies for all on-board voltages. A large number of configurable I/Os is provided via rugged high-speed stacking strips. All modules in 5 x 4 cm form factor are fully mechanically and largely electrically compatible among them. All this on a tiny footprint, smaller than a credit card, at the most competitive price. A free and open embedded development suite with reference designs is included.

  • 34MHz to 4.4GHz Frequency Synthesizer

    Zachtek

    A serial controllable synthesizer that will output any frequency between 33MHz to 4.4GHz. Arduino Pro Mini + ADF4351. It's a frequency generator that you control using serial commands. The synth has a built-in pre-programmed Arduino Pro Mini that runs a commands parser so you can set any frequency simply by sending is over the serial port. It can be run on voltages from 3,3V to 5V and takes about 140mA of current. There are two complimentary 50 ohms outputs that give out 0dBm. The output is pretty flat over the entire frequency range. It has a stability of 2.5ppm (parts per million) or better when using the built-in TCXO 10MHz reference.

  • ATE For ADC Module

    MS 1527 - Meltronics Systemtech

    The Semi-ATE is used for testing the analog ADC. It shall carry out the functional test on ADC analog module. The ATE shall have all necessary IO signals on the connector end. The semi-ATE can carry out the functional tests on ADC analog module with host PC or laptop. It provides +15V, -15V, +5V & -5V to module and +2.5V high precision reference voltage. It can able to control keysight N6700B Power supply mainframe using RS422 interface.

  • PWM to Voltage Output D/A Converters

    Analog Devices Inc.

    Analog Devices’ pulse-width modulation (PWM) to voltage output D/A converters convert a PWM input to an accurate, stable, buffered voltage without the ripple, slow settling, and external passive components of discrete filter implementations. Our PWM D/A converters measure the period and pulse width of a PWM input signal and immediately update the D/A converter output with up to 12-bit accuracy and no software coding required. This family of D/A converters is available with 8-bit to 12-bit resolution, dual and quad channels, integrated references, and with high temperature operation. Applications include isolated motor control, automotive headlights or industrial lighting, and other applications that benefit from the simple control interface.

  • DC - 400 MHz PC-Based Timer Interval Analyzer

    Guide Technology, Inc.

    GuideTech’s GT658PCI is an ultra-fast, high resolution, DC – 400 MHz Time Interval Analyzer (TIA), ideal for most PC-based lab bench (timing) test applications. What makes the GT 658 superior to traditional counters is analogous to the difference between volt meters & digital scopes. While both measure voltage, the scope provides much more information about the dynamics of the signal. This is because our patented TIA substantially increases measurement speed, and the measurements are displayed as afunction of time. All of these features, along with the benefit of ‘continuous time correlation to a common reference between all measurement time stamps,’ enable our TIAs to make measurements that weren’t previously possible with traditional counters.

Get Help